Updated
Enter the fiber, its length and how many connectors and splices are in the path. You get the expected link loss line by line, using TIA-568.3-D values you can change, and whether it fits the optic's loss budget. It runs in your browser.
| Item | Calculation | Loss |
|---|
Formula: loss = length (km) × attenuation (dB/km) + connector pairs × loss per pair + splices × loss per splice + other.
The fiber distance chart lists every optic here with its reach on OM1 to OM5 and single-mode. Identifying the fiber in front of you? The fiber color code covers jacket, connector and tube colors.
The calculator starts from the maximums TIA-568.3-D allows for installed components. Real parts are usually better; use their datasheet figures when the design depends on it.
| Component | Maximum loss | Source |
|---|---|---|
| Multimode cable, 850 nm | 3.5 dB/km | TIA-568.3-D |
| Multimode cable, 1300 nm | 1.5 dB/km | TIA-568.3-D |
| Single-mode inside plant cable, 1310 / 1550 nm | 1.0 dB/km | TIA-568.3-D |
| Single-mode outside plant cable, 1310 / 1550 nm | 0.5 dB/km | TIA-568.3-D |
| Mated connector pair | 0.75 dB | TIA-568.3-D |
| Splice (fusion or mechanical) | 0.3 dB | TIA-568.3-D |
ISO/IEC 11801 uses its own cabled-fiber figures: OS1 1.0 dB/km and OS2 0.4 dB/km at 1310 and 1550 nm. Enter 0.4 under Loss values to design to OS2.
The most loss each optic's standard allows between the two transceivers (maximum channel insertion loss), connectors and splices included. Only optics whose figure we could confirm are listed; for the rest, compare with the module's datasheet Tx and Rx values.
| Optic | Fiber | Wavelength | Reach | Max channel loss | Standard |
|---|---|---|---|---|---|
| 1000BASE-SX | OM1 | 850 nm | 275 m | 2.53 dB | IEEE IEEE 802.3z (Clause 38) |
| 1000BASE-SX | OM2 | 850 nm | 550 m | 3.56 dB | IEEE IEEE 802.3z (Clause 38) |
| 1000BASE-SX | OM3 | 850 nm | 550 m | 3.56 dB | IEEE IEEE 802.3z (Clause 38) |
| 1000BASE-SX | OM4 | 850 nm | 550 m | 3.56 dB | IEEE IEEE 802.3z (Clause 38) |
| 1000BASE-SX | OM5 | 850 nm | 550 m | 3.56 dB | IEEE IEEE 802.3z (Clause 38) |
| 1000BASE-LX on multimode | OM1 | 1310 nm | 550 m | 2.35 dB | IEEE IEEE 802.3z (Clause 38) |
| 1000BASE-LX on multimode | OM2 | 1310 nm | 550 m | 2.35 dB | IEEE IEEE 802.3z (Clause 38) |
| 1000BASE-LX on multimode | OM3 | 1310 nm | 550 m | 2.35 dB | IEEE IEEE 802.3z (Clause 38) |
| 1000BASE-LX on multimode | OM4 | 1310 nm | 550 m | 2.35 dB | IEEE IEEE 802.3z (Clause 38) |
| 1000BASE-LX on multimode | OM5 | 1310 nm | 550 m | 2.35 dB | IEEE IEEE 802.3z (Clause 38) |
| 10GBASE-SR | OM1 | 850 nm | 33 m | 1.60 dB | IEEE IEEE 802.3ae (Clause 52) |
| 10GBASE-SR | OM2 | 850 nm | 82 m | 1.80 dB | IEEE IEEE 802.3ae (Clause 52) |
| 10GBASE-SR | OM3 | 850 nm | 300 m | 2.60 dB | IEEE IEEE 802.3ae (Clause 52) |
| 10GBASE-SR | OM4 | 850 nm | 400 m | 2.90 dB | IEEE IEEE 802.3ae (Clause 52) |
| 10GBASE-SR | OM5 | 850 nm | 400 m | 2.90 dB | IEEE IEEE 802.3ae (Clause 52) |
| 25GBASE-SR | OM3 | 850 nm | 70 m | 1.80 dB | IEEE IEEE 802.3by (Clause 112) |
| 25GBASE-SR | OM4 | 850 nm | 100 m | 1.90 dB | IEEE IEEE 802.3by (Clause 112) |
| 25GBASE-SR | OM5 | 850 nm | 100 m | 1.90 dB | IEEE IEEE 802.3by (Clause 112) |
| 40GBASE-SR4 | OM3 | 850 nm | 100 m | 1.90 dB | IEEE IEEE 802.3ba (Clause 86) |
| 40GBASE-SR4 | OM4 | 850 nm | 150 m | 1.50 dB | IEEE IEEE 802.3ba (Clause 86) |
| 40GBASE-SR4 | OM5 | 850 nm | 150 m | 1.50 dB | IEEE IEEE 802.3ba (Clause 86) |
| 100GBASE-SR10 | OM3 | 850 nm | 100 m | 1.90 dB | IEEE IEEE 802.3ba (Clause 86) |
| 100GBASE-SR10 | OM4 | 850 nm | 150 m | 1.50 dB | IEEE IEEE 802.3ba (Clause 86) |
| 100GBASE-SR10 | OM5 | 850 nm | 150 m | 1.50 dB | IEEE IEEE 802.3ba (Clause 86) |
| 100GBASE-SR4 | OM3 | 850 nm | 70 m | 1.80 dB | IEEE IEEE 802.3bm (Clause 95) |
| 100GBASE-SR4 | OM4 | 850 nm | 100 m | 1.90 dB | IEEE IEEE 802.3bm (Clause 95) |
| 100GBASE-SR4 | OM5 | 850 nm | 100 m | 1.90 dB | IEEE IEEE 802.3bm (Clause 95) |
| 1000BASE-LX | Single-mode | 1310 nm | 5 km | 4.57 dB | IEEE IEEE 802.3z (Clause 38) |
| 10GBASE-LR | Single-mode | 1310 nm | 10 km | 6.20 dB | IEEE IEEE 802.3ae (Clause 52) |
| 40GBASE-LR4 | Single-mode | 1310 nm | 10 km | 6.70 dB | IEEE IEEE 802.3ba (Clause 87) |
| 100GBASE-LR4 | Single-mode | 1310 nm | 10 km | 6.30 dB | IEEE IEEE 802.3ba (Clause 88) |
| 100G CWDM4 | Single-mode | 1310 nm | 2 km | 5.00 dB | MSA 100G CWDM4 MSA |
| 100GBASE-DR | Single-mode | 1310 nm | 500 m | 3.00 dB | IEEE IEEE 802.3cd (Clause 140) |
| 100GBASE-FR1 | Single-mode | 1310 nm | 2 km | 4.00 dB | IEEE IEEE 802.3cu (Clause 140) |
| 100GBASE-LR1 | Single-mode | 1310 nm | 10 km | 6.30 dB | IEEE IEEE 802.3cu (Clause 140) |
| 400GBASE-DR4 | Single-mode | 1310 nm | 500 m | 3.00 dB | IEEE IEEE 802.3bs (Clause 124) |
| 400GBASE-FR4 | Single-mode | 1310 nm | 2 km | 4.00 dB | IEEE IEEE 802.3cu (Clause 151) |
Add up every part of the link: length in km times the cable's attenuation in dB/km, plus the loss of each mated connector pair, plus the loss of each splice, plus anything else in the path such as a splitter. With TIA-568.3-D maximums, 300 m of OM3 at 850 nm with two connector pairs is 0.3 × 3.5 + 2 × 0.75 = 2.55 dB.
TIA-568.3-D allows up to 0.75 dB per mated connector pair and 0.3 dB per splice, fusion or mechanical. Good field terminations are usually well under that, but the maximums are what a design should assume unless the components are specified lower.
When you compare with an optic's power budget (minimum transmit power minus receiver sensitivity), a common rule of thumb is to keep at least 3 dB spare for aging, repairs and dirty connectors. IEEE 802.3's maximum channel insertion loss already sets aside the optic's penalties, so a link just under it meets the standard, though spare headroom for future repairs is still wise.
On multimode fiber, modal bandwidth limits reach before loss does. 10GBASE-SR is specified to 300 m on OM3 regardless of how low the loss is, so check the distance as well; the calculator flags a run longer than the optic's reach.
No. The calculator runs on this page in your browser, and the page has no analytics or tracking. Your entries are kept in the part of the link after the # so you can share a result, and browsers never send that part to the server.
In NetworkSketch, a link carries its media type, speed, length, cable ID and certification result, and the PDF export prints them in a cabling schedule next to the drawing.